Model UT106: OPERATING MANUAL
Overview
Unpacking Inspection
Safety Information
Rules For Safe Operation
Automotive Servicing Safety Guide
International Electrical Symbols
The Meter Structure
Rotary Switch
Functional Buttons
Display Symbols
Measurement Operation
Part 1 Multimeter Basic Testing
A. DC Voltage Testing
B. AV Voltage Testing
C. DC Current Testing
D. Resistance Testing
E. Diode Testing
F. Continuity Testing
G. Temperature Measurement
H. Frequency Measurement
I. Dwell Testing
J. Engine Tach (Rotation Speed)
Testing “RPMx10”
K. Operation of Hold Mode
Part 2 Diagnosis of Automotive Troubles
A. Fuse Testing: Check the fuse to see if
it is blown out
B. Switch Testing: Check the switch to see
if it can work correctly
C. Solenoid or Relay Testing
D. Starting/Charging System Testing
E. Battery Power Consumption Testing
when the Engine Is off
Seitenansicht 0
1 2 3 4 5 6 ... 59 60

Inhaltsverzeichnis

Seite 1 - Model UT106: OPERATING MANUAL

Table of ContentsTitle Page 134457910111112131313151719212324252627282929303031

Seite 2

The Meter Structure (see figure 1)1. LCD display 2. Data Hold button3. Rotary Switch 4. Input Terminals5. Power button(figure 1)

Seite 3 - Overview

Rotary SwitchRotarySwitchPositionFunctionVkHz0CADWELLRPM x 10DC voltage measurement.AC voltage measurement.Resistance measurement.Diode test.Continuit

Seite 4 - Safety Information

Display Symbols (see figure 2)The battery is low. Warning: To avoid false readings,which could lead to possible electricshock or personal injury, r

Seite 5 - Rules For Safe Operation

V13Model UT106: OPERATING MANUALMeasurement OperationPart 1 Multimeter Basic TestingA. DC Voltage Testing (see figure 3)( figure 3)WarningTo avoid h

Seite 6

Note 14Model UT106: OPERATING MANUALIf the value of voltage to be measured is unknown,use the maximum measurement position (1000V) andreduce the range

Seite 7

15Model UT106: OPERATING MANUALB. AC Voltage Testing (see figure 4)( figure 4)WarningTo avoid harms to you or damages to the Meter fromelectric shock,

Seite 8

Note16Model UT106: OPERATING MANUALIf the value of voltage to be measured is unknown,use the maximum measurement position (1000V) andreduce the range

Seite 9

A17Model UT106: OPERATING MANUALC. DC Current Testing (see figure 5)WarningBefore connecting the Meter in serial to the testedin-circuit, disconnect i

Seite 10 - (figure 1)

Note 18Model UT106: OPERATING MANUALIf the value of current to be measured is unknown, usethe maximum measurement position (10A) and 10Aterminal, and

Seite 11 - Rotary Switch

19Model UT106: OPERATING MANUALD. Resistance Testing (see figure 6)( figure 6)WarningTo avoid damages to the Meter or to the devicesunder test, disco

Seite 12

Title Page 2Model UT106: OPERATING MANUAL33343637373839404142434446464749515252

Seite 13 - Measurement Operation

Note 20Model UT106: OPERATING MANUALThe test leads can add 0.1 to 0.2 of error to theresistance measureme

Seite 14

21Model UT106: OPERATING MANUALE. Diode Testing (see figure 7)WarningTo avoid possible damage to the Meter and to thedevice under test, disconnect ci

Seite 15

Note 22Model UT106: OPERATING MANUALIn a circuit, a good diode should still produce a forwardvoltage drop reading of 0.5V to 0.8V; however, thereverse

Seite 16

Note23Model UT106: OPERATING MANUALF. Continuity Testing (see figure 7)WarningTo avoid possible damage to the Meter and to thedevice under test, disc

Seite 17

Note24Model UT106: OPERATING MANUALG. Temperature Measurement (see figure 8)( figure 8)WarningTo avoid harm to yourselves , never attempt to inputan e

Seite 18

Note25Model UT106: OPERATING MANUALH. Frequency Measurement (see figure 9)WarningTo avoid harm to yourselves , never attempt to inputan effective volt

Seite 19

26Model UT106: OPERATING MANUALI. Dwell Testing (see figure 10)It was very important in the past to test the dwell of thecut-off switch of an ignitio

Seite 20

27Model UT106: OPERATING MANUALJ. Engine Tach (Rotation Speed) Testing “RPMx10” (see figure 11)The RPM means the rotating frequency of the main sha

Seite 21

28Model UT106: OPERATING MANUALK. Operation of Hold ModeThe Hold mode is applicable to all measurement fun

Seite 22

29Model UT106: OPERATING MANUALPart 2 Diagnosis of Automotive TroublesThe Meter UT106 is a tool for the very effective diagnosisof the troubles with

Seite 23

Overview 3Model UT106: OPERATING MANUALThis Operating Manual covers information on safety andcautions. Please read the relevant information carefully

Seite 24 - Black Red

Model UT106: OPERATING MANUALB. Switch Testing: Check the switch to see if it canwork correctly.The same as in Items 1 to 3 (Fuse Testing).Connect th

Seite 25

31Model UT106: OPERATING MANUALD. Starting/Charging System TestingSet the rotary switch to 20 VDC.As prompted at the LCD connect terminal, insert ther

Seite 26

A32Model UT106: OPERATING MANUALE. Battery Power Consumption Testing when theEngine Is offThe test is carried out to find the amperage of the powercon

Seite 27

33Model UT106: OPERATING MANUALF. Trigger Voltage Battery Load TestingSet the rotary switch to 20 VDC.As prompted at the LCD connect terminal, insert

Seite 28

34Model UT106: OPERATING MANUALG. Voltage Drop TestingCut off the ignition system so as to disable the startof the automobile.Cut off the main igniti

Seite 29

35Model UT106: OPERATING MANUALComponentVoltageSwitchLeadGroundingBattery Lead ConnectorWiring300 mV200 mV100 mV50 mV0.0 VCompare the readings of the

Seite 30

36Model UT106: OPERATING MANUALH. Charging System Voltage TestingThis testing is used to see if the chargi

Seite 31

37Model UT106: OPERATING MANUALI. Ignition System Testing1. Ignition Coil TestingBefore the operation, cool the engine and cut off theignition coil.Se

Seite 32

38Model UT106: OPERATING MANUALSet the rotary switch to the 200k and test the primarycoil of the ignition coil.Connect the red test lead probe to th

Seite 33

39Model UT106: OPERATING MANUALWarningSome of Chrysler’s products use a spark plug highvoltage damper with “positive lock” end electrodes,which can on

Seite 34

This Meter complies with standards IEC61010: in pollutiondegree 2, overvoltage category (CAT. II 1000V, CAT. III600V) and double insulation.CAT.II: Lo

Seite 35

40Model UT106: OPERATING MANUALMove the Hall sensor out of the automobile and seethe details of the operation in various kinds ofautomotive manuals.Co

Seite 36

41Model UT106: OPERATING MANUAL5. RPMx10 Testing (see figure 17)Set the rotary switch to RPMx10 and select thenumber of cylinders in the automobile to

Seite 37

42Model UT106: OPERATING MANUAL6. Fuel System Testing(1) GM (General Motor):It is necessary to add more accurate engine fuel controlto a low injection

Seite 38 - Spark Plug

43Model UT106: OPERATING MANUALThe testing method is similar to that of the resistance ofan ignition coil.Cut the electric link off the injector. (Re

Seite 39

44Model UT106: OPERATING MANUAL1. Oxygen SensorThe oxygen sensor is used to test the oxygen content inthe

Seite 40

45Model UT106: OPERATING MANUALThe zirconia sensor is tested with the 2VDC. Asprompted at the LCD connect terminal, insert the redtest lead into the

Seite 41 - Ignition Coil

46Model UT106: OPERATING MANUAL2. Temperature Sensor (see figure 20)(figure 20)HeaterTemperatureSensorRed BlackTesting Procedure:The same as in the r

Seite 42 - Fuel Injector

47Model UT106: OPERATING MANUALThe position sensor is an electrometer or variableresistance. It is used for the computer monitoring of theposition an

Seite 43 - Long Fuel Short Fuel

48Model UT106: OPERATING MANUALThe MAP sensor is used to change a pressure signalinto a DC voltage or frequency one. All GM, Chrysler,Honda and Toyot

Seite 44

49Model UT106: OPERATING MANUAL5. Mass Air Flow (MAF) Sensor (see figure 23)(figure 23)Black RedGroundLow frequency MAF Sensor of GM(General Motor) in

Seite 45

5Model UT106: OPERATING MANUALRules For Safe OperationWarningTo avoid possible electric shock or personal injury,and to avoid possible damage to the

Seite 46

50Model UT106: OPERATING MANUALWarningThe reading becomes the actual RPM only after itis multiplied by 10.Frequency = RPM/30. (This only applies to

Seite 47

General Specifications51Model UT106: OPERATING MANUALMaximum Voltage between any Terminals andgrounding: Refer to different range input protectionvol

Seite 48

A. DC VoltageB. AC Voltage 52Model UT106: OPERATING MANUALAccurate SpecificationsAccuracy: (a% Reading +

Seite 49

C. DC CurrentD. ResistanceE. Diode53Model UT106: OPERATING MANUALRange Resolution AccuracyOverloadProtection200mA10A0.1 mA10 mA(0.8%+5)(1.2%+5)Fuse 31

Seite 50

F. Continuity TestingG. TemperatureH. Frequency 54Model UT106: OPERATING MANUALRange ResolutionOverloadProtection1600VpRemark:Open circuit voltage app

Seite 51

I. Dwell TestingJ. Tach (Rotation Speed) Testing55Model UT106: OPERATING MANUALRange Resolution AccuracyOverloadProtection4CYL6CYL8CYL (3%+5)600 Vp0.1

Seite 52 - Accurate Specifications

56Model UT106: OPERATING MANUALMaintenanceThis section provides basic maintenance informationincluding battery and fuse replacement instruction.Warnin

Seite 53

57Model UT106: OPERATING MANUALB. Replacing the Fuses (see figure 24)WarningTo avoid electrical shock or arc blast, or personalinjury or damage to the

Seite 54

58Model UT106: OPERATING MANUALBatteryOpen up ScrewC. Replacing the Battery (see figure 25)WarningTo avoid false readings, which could lead to possib

Seite 55

59Model UT106: OPERATING MANUAL

Seite 56 - Maintenance

6Model UT106: OPERATING MANUALIf the value of current to be measured is unknown,use the maximum measurement position, andreduce the range step by st

Seite 57

Copyright 2005 Uni-Trend Group Limited.All rights reserved.Manufacturer:Uni-Trend Technology (Dongguan) LimitedDong Fang Da DaoBei Shan Dong Fang Indu

Seite 58 - Open up Screw

7Model UT106: OPERATING MANUALAutomotive Servicing Safety GuideWarningAs some automobiles are installed with safety airbags, you must pay attention

Seite 59

8Model UT106: OPERATING MANUALA. The data of the automotive servicing manual haveoriginated from the automotive servicing information.Contact the lo

Seite 60

International Electrical SymbolsAC (Alternating Current).DC (Direct Current)Grounding.Double Insulated.Deficiency of Built-In Battery.Fuse.Warning. R