UT205/206Operating ManualCertificate No. 956661Digital Clamp MultimeterRegistered Design No.: 0011438.1M001P/N : 4141030
9Turn the display backlight on and off.1. Press to start the frequency counter; the Meter beeps.2. Press again to enter duty cycle mode; the Meter bee
10Functional Buttons (2)Switches between DC and AC voltage; the Meter beeps. DC voltage is default.Model UT205: Switches between diode and continuity
11Display Symbols (1) (See figure 2)MeaningIndicator for AC voltage or current. The displayed value is the mean value.Indicator for DC voltage. The di
12Display Symbols (2) (See figure 2)Ω: Ohm. The unit of resistance.kΩ: kilohm. 1 x 103 or 1000 ohms.MΩ: Megaohm. 1 x 106 or 1,000,000 ohms.F: Fa
13Measurement Operation (1)A. DC Voltage Measurement (See figure 3) WarningTo avoid harms to you or damages to the Meter from electric shock, please
14Measurement Operation (2)B. AC Voltage Measurement (See figure 4) WarningTo avoid harms to you or damages to the Meter from electric shock, please
15Measurement Operation (3)C. Measuring Resistance (See figure 5) WarningTo avoid damages to the Meter or to the devices under test, disconnect circ
16Measurement Operation (4) • When resistance measurement has been completed, disconnect the connection between the testing leads and the circuit un
17E. Testing Diodes (See figure 7) WarningTo avoid possible damage to the Meter and to the device under test, disconnect circuit power and discharge
18 • When diode testing has been completed, disconnect the connection between the testing leads and the circuit under test, and remove the testing
1TitleOverviewUnpacking InspectionSafety InformationRules For Safe OperationInternational Electrical SymbolsThe Meter StructureRotary SwitchFunctional
19 • The LCD displays indicating the tested capacitor is shorted or it exceeds the maximum range. • When capacitance measurement has been complet
20H. Measuring Duty Cycle (See figure 10)The duty cycle measurement range is: 0.1%~99.9%. To measure duty cycle, do the following:1. Set up the Meter
21I. Model UT206: Temperature Measurement (See figure 11)The temperature measurement range is -40˚C~1000˚C. To measure temperature, connect the Meter
22J. AC Current Measurement (See figure 12) WarningTo avoid electric shock, never measure current while the test leads are inserted into the input t
23 WarningTo avoid possibility of electric shock, do not use Hold mode to determine if circuits are without power. The Hold mode will not capture un
24It uses for selecting the required measurement function when there is more than one function at one position of the rotaryswitch.The BLUE button W
25600V rms.1000A AC rms continuous.40mm.Digital: 3999Updates 3 times/second.Operating: 5˚C to +35˚C (41˚F to +95˚F). Storage: -10˚C to +50˚C (14˚F to
26Accuracy: ± (a% reading + b digits), guarantee for 1 year.Operating temperature 23˚C±5˚C.Relative humidity <75%.Temperature coefficient: 0.1 x (s
27Accuracy Specifications (2)RangeDiodeResolution1mVOverload Protection600VpE. Diode TestRemarks: • Open circuit voltage approximate 1.48V. • Displa
28Accuracy Specifications (3)Range10Hz100Hz1kHz10kHz100kHz1MHz10MHz0.1%~99.9%Resolution0.001Hz0.01Hz0.1Hz1Hz10Hz100Hz1kHz0.01%Accuracy±(0.1%+3)Overloa
2This Operating Manual covers information on safety and cautions. Please read the relevant information carefully andobserve all the Warnings and Notes
29This section provides basic maintenance information including battery replacement instruction. WarningDo not attempt to repair or service your Mete
30~ END ~This operating manual is subject to change without notice.Model UT205/UT206: OPERATING MANUALUni-Trend International Limited. © Copyright 200
31Model UT205/UT206: OPERATING MANUAL
32Model UT205/UT206: OPERATING MANUALManufacturer:Uni-Trend International LimitedRm901, 9/F, Nanyang Plaza57 Hung To Road, Kwun TongKowloon, Hong Kong
3Unpacking InspectionOpen the package case and take out the Meter. Check the following items carefully to see any missing or damaged part:In the event
4This Meter complies with the standards IEC61010: in pollution degree 2, overvoltage category (CAT. III 600V) and double insulation.CAT. III: Distribu
5 WarningTo avoid possible electric shock or personal injury, and to avoid possible damage to the Meter or to the equipmentunder test, adhere to the
6Rules For Safe Operation (2)Remove test leads, temperature probe and test clip from the Meter and turn the Meter power off before opening the Meter c
7The Meter Structure (See figure 1)Transformer Jaws designed to pick up the AC current flowing through the conductor.The Jaw Opening Light.HOLD button
8Rotary SwitchBelow table indicated for information about the rotary switch positions.Rotary SwitchPositionFunctionTurn on or off the Meter.AC voltage