Table of Contents
Title
Overview
Unpacking Inspection
Safety Information
Rules For Safe Operation
International Electrical Symbols
The Meter Structure
Rotary Switch
Functional Buttons
Display Symbols
Measurement Ranges
A. Selecting a Measurement Range
B. Manual Ranging and Autoranging
Measurement Operation
A. AC Voltage Measurement
B. DC Voltage Measurement
C. DC Milivolt Measurement
D. Measuring Continuity, Resistance,
Conductance & Capacitance
E. Testing Diodes
F. DC or AC Current Measurement
G. Frequency & Duty Cycle Measurement
MAX MIN Recording Mode
PEAK MAX MIN Mode
Operation of Hold Mode
Operation of Auto Hold Mode
The Use of Relative Value and Relative
Percentage Value Mode
Turning on the Display Backlight
Analogue Bar Graph Display
Full Icons Display
Sleep Mode
General Specifications
Model UT70C: OPERATING MANUAL
1
Seitenansicht 0
1 2 3 4 5 6 ... 47 48

Inhaltsverzeichnis

Seite 1 - Table of Contents

Page34568891012141414161617181923242628303132333434353536Table of ContentsTitleOverviewUnpacking InspectionSafety InformationRules For Safe OperationI

Seite 2

Functional Buttons (1)Below table indicated for information about the functionalbutton operations.Button Operation PerformedMeasuringFunctionContinuit

Seite 3 - Overview

HOLD Any rotaryswitchpositionPress HOLD to enter and exit theHold mode in any mode; theMeter beeps.Functional Buttons (2)ConductancemodePress HOLD to

Seite 4 - Unpacking Inspection

No. MeaningSymbolDisplay Symbols (1) (see figure 2)(figure 2)1The Meter is in the auto range mode inwhich the Meter automatically selects therange wit

Seite 5 - Safety Information

V, mVDisplay Symbols (2)12 ,k , MW: Ohm. The unit of resistance.kW: kilohm. 1 x 103 or 1000 ohms.MW: Megohm. 1 x 106 or 1,000,000ohms.Hz, kHz,MH

Seite 6 - Rules For Safe Operation (1)

Measurement Ranges (1)A measurement range determines the highest value theMeter can measure. Most Meter functions have morethan one range. See "

Seite 7 - Rules For Safe Operation (2)

1. Press RANGE.The Meter enters the manual range mode and turns off.Each presses of RANGE increments the range.When the highest range is reache

Seite 8

Measurement Operation (1)A. AC Voltage Measurement (see figure 3)WarningTo avoid harms to you or damages to the Meter fromelectric shock, please do n

Seite 9 - Rotary Switch

(figure 4)B. DC Voltage Measurement (see figure 4)Measurement Operation (2)WarningTo avoid harms to you or damages to the Meter fromelectric shock, pl

Seite 10 - Functional Buttons (1)

(figure 5)Measurement Operation (3)C. DC Millivolt Measurement (see figure 5)WarningTo avoid harms to you or damages to the Meter fromelectric shock

Seite 11 - Functional Buttons (2)

(figure 6)Measurement Operation (4)D. Measuring Continuity, Resistance,Conductance & CapacitanceWarningTo avoid damages to the Meter or to the dev

Seite 12 - Model UT70C: OPERATING MANUAL

Page373737383838393940414142434445454546Accuracy SpecificationsA. AC VoltageB. DC VoltageC. Continuity, Resistance & Conductance Tes

Seite 13 - Display Symbols (2)

(figure 7)Resistance Measurement (see figure 7)Measurement Operation (5)The resistance ranges are: 800.0 , 8.000k , 80.00k ,800.0k , 8.000M

Seite 14 - Measurement Ranges (1)

Measurement Operation (6)l The LCD displays indicating open-circuit for thetested resistor or the resistor value is higher thanthe maximum range of t

Seite 15 - Measurement Ranges (2)

(figure 9)Measurement Operation (7)Capacitance Measurement (see figure 9)The Meter's capacitance ranges are: 1.000nF, 10.00nF,100.0nF, 1.000F, 10

Seite 16 - Measurement Operation (1)

Measurement Operation (8)E. Testing Diodes (see figure 10)(figure 10)WarningTo avoid possible damage to the Meter and to thedevice under test, disconn

Seite 17 - Measurement Operation (2)

(figure 11)Measurement Operation (9)Notel In a circuit, a good diode should still produce aforward voltage drop reading of 0.5V to 0.8V;however, the r

Seite 18 - Measurement Operation (3)

Measurement Operation (10)The current measurement has 2 measurement positionson the rotary switch: A and mA .The A has a 8.000A and 10.00A range, with

Seite 19 - Measurement Operation (4)

(figure 12)Measurement Operation (11)G. Frequency & Duty Cycle Measurement (see figure 12)Frequency MeasurementThe measurement ranges are: 1kHz, 1

Seite 20 - Measurement Operation (5)

Measurement Operation (12)Duty Cycle MeasurementThe duty cycle measurement range is 0.01% ~ 99.99%.To measure duty cycle:1. Set up the Meter to measur

Seite 21 - Measurement Operation (6)

MAX MIN recording mode applies to all measurementfunctions except at conductance measurement function.MAX MIN recording mode captures and stores thema

Seite 22 - Measurement Operation (7)

MAX MIN Recording Mode (2)To selectresponse timel The pre-set response time is 100ms.l Press to select 1 ms responsetime in REC mode. It is calledun

Seite 23 - Measurement Operation (8)

OverviewThis Operating Manual covers information on safety andcautions. Please read the relevant information carefullyand observe all the Warnings and

Seite 24 - Measurement Operation (9)

PEAK MAX MIN Mode (see figure 14)(figure 14)PEAK MAX MIN mode is an additional function of .Pressing to toggle between 100ms response timeand 1ms re

Seite 25 - Measurement Operation (10)

Operation of Hold ModeWarningTo avoid possibility of electric shock, do not useHold mode to determine if circuits are without power.The Hold mode will

Seite 26 - Select Hz

Operation of Auto Hold ModeAuto Hold means you no need to press HOLD, thereadings on the LCD will be hold automatically.Conditions to enter Auto Hold

Seite 27 - Measurement Operation (12)

The Use of Relative Value and RelativePercentage Value ModeThe and % mode applies to all measurement functions,with auto ranging.REL mode can be

Seite 28 - Present value

Turning on the Display BacklightWarningIn order to avoid the hazard arising from mistakenreadings in insufficient light or poor vision, pleaseuse the

Seite 29 - MAX MIN Recording Mode (2)

Full Icons DisplayIf the Meter is turned on with any functional button beingpressed on, the LCD will display all the icons and maintainthis mode until

Seite 30 - Select 1ms

l Maximum Displayl Temperaturel Relative Humidityl Altitudel Battery Typel Battery Deficiencyl Data Holdingl Negative readingl Overloadingl Equipped w

Seite 31 - Operation of Hold Mode

Accuracy Specifications (1)Accuracy: (a% reading + b digits), guarantee for 1 year.Operating temperature: 23oC5oC.Relative humidity: <80%.Temperatu

Seite 32 - Operation of Auto Hold Mode

Approximate100(0.5%+3)(0.5%+1)(2%+3)(2%+10)Accuracy Specifications (2)C. Continuity, Resistance & Conductance TestContinuity Test(800.0 )8008k80

Seite 33 - Percentage Value Mode

Accuracy Specifications (3)F. DC CurrentRangeResolutionAccuracyOverloadProtection(0.3%+2)80mA800mA8A10A10 A100 A1mA10mARemark:l At 8A & 10A Range:

Seite 34 - Analogue Bar Graph Display

Unpacking InspectionOpen the package case and take out the Meter. Checkthe following items carefully to see any missing ordamaged part:In the event y

Seite 35 - Sleep Mode

Accuracy Specifications (4)H. Frequency & Duty CycleFrequency - At mV RangeRemarks:l Input sensitivity as follows:<100kHz: 100mV rms;100kHz: 5

Seite 36 - General Specifications

Maintenance (1)This section provides basic maintenance informationincluding battery and fuse replacement instruction.WarningDo not attempt to repair o

Seite 37 - Accuracy Specifications (1)

Maintenance (2)B. Testing the FusesWarningTo avoid electrical shock or personal injury, removethe test leads and any input signals before replacingthe

Seite 38 - Accuracy Specifications (2)

WarningTo avoid false readings, which could lead to possibleelectric shock or personal injury, replace the batteryas soon as the battery indicator &qu

Seite 39 - Accuracy Specifications (3)

Maintenance (4)D. Replacing the Fuses (see figure 15)WarningTo avoid electrical shock or arc blast, or personalinjury or damage to the Meter, use spec

Seite 40 - Accuracy Specifications (4)

Receiving DataTransmitting DataData Terminal ReadyGroundingData Set ReadyRequest to SendClear to SendRXTXDTRGNDDSRRTSCTS3220764523456782345678RS232C S

Seite 41 - Accuracy Specifications (5)

RS232C Serial Port (2)C. System Requirements for Installing the UT70CInterface ProgramTo use UT70C Interface Program, you need the followinghardware a

Seite 42 - Maintenance (2)

Model UT70C: OPERATING MANUAL 47

Seite 43 - The Meter

Manufacturer: UNI-TREND TECHNOLOGY(DONG GUAN)LIMITEDAddress: Dong Fang Da Dao, Bei Shan Dong Fang Industrial Development District, Hu Me

Seite 44 - Maintenance (4)

Safety InformationCAT. II: Local level, appliance, PORTABLE EQUIPMENTetc., with smaller transient voltage overvoltages thanCAT. IIICAT. III: Distribut

Seite 45 - RS232C Serial Port (1)

Rules For Safe Operation (1)WarningTo avoid possible electric shock or personal injury,and to avoid possible damage to the Meter or to theequipment un

Seite 46 - RS232C Serial Port (2)

Rules For Safe Operation (2)l Disconnect circuit power and discharge all high-voltage capacitors before testing resistance,conductance, continuity, di

Seite 47

International Electrical SymbolsThe Meter Structure (see figure 1)(figure 1)1 Front Case2 LCD Display3 Functional Buttons4 Rotary Switch5 Input T

Seite 48

mVVOFFVRotary SwitchBelow table indicated for information about the rotaryswitch positions.RotarySwitchPositionFunctionPower is turned off.AC voltage