RS-232 TO AMX 192
In this application, a personal computer may send ascii commands to operate individual dimmer channels.
CONNECTOR OPERATION
Microplex IN Not Used
Microplex OUT Not Used
DMX IN Not used
*DMX out Output AMX 192 (64 or 128)
MIDI / Analog Not used
Luma-net Not Used
RS-232 Input RS-232
JUMPER LOCATIONS
P4 & 5 P7 JP6 & 7 JP8 & 9 JP10 JP11 JP12 JP13
OPEN OPEN 1-2 N/A 2-3 2-3 1-2 2-3
P6 P8 JP1 DMX OUT CABLE
N/A N/A POS 5 OR 6 (BELOW) JP3
DIPSWITCH POSITIONS
C1 C2 C3 C4 ADDRESS 1 - 7 A8
DN UP UP DN N/A DN:64
Baudrate is either 9600 (JP1 - 6) or 2400 (JP1 - 5) with 8 data bits, 1 stop bit, no parity
Dimmer channels 1 to 100 can be controlled with these simple ASCII commands:
ASCII characters supported: F D G R - @ + : . 0-9
Fxx:xx.x (FADERATE, x=fade time in minutes : seconds . tenths),
Dccc-ccc@xxx (DIMMER LEVEL, c=channel number, -=to, +=and, x= level)
G (EXECUTE) R (RESET or BLACKOUT)
Carriage return after each command. Max fade time is 50 minutes.
Max fade time is 50 minutes.
AMX output is sent as either 64 or 128 channels, depending on the setting of switch A8.
*IMPORTANT - Move AMX output connector jumper from JP4 to JP3.
INTERFACE UNIT
Software Revision 1.05, Version A RS-232 TO AMX 192
NSI CORPORATION 12